Optical Imaging
NEWTON Series
Optical Imaging (BLI and FLI in VIS, NIR-I & SWIR)
Advanced bioluminescence, visible fluorescence, NIR-I, and SWIR (NIR-II) imaging for preclinical research
Quick Resources
Access key Newton resources and technical documents
Brochure
Product overview and key capabilities.
References
Publications and supporting research.
NEWTON Series System Overview
The NEWTON series offers advanced bioluminescence, fluorescence multispectral imaging, and optional X-Ray capabilities for a wide range of applications.
Built on a shared technological foundation, NEWTON systems deliver consistent performance, scalable configurations, and reliable quantitative results for diverse in vivo, ex vivo, and in vitro applications. Designed for longitudinal preclinical research, the NEWTON systems deliver non-ionizing and non-invasive visualization of biological processes in the visible, near infrared and short-wave infrared spectra (VIS / NIR / SWIR). Whether your focus is oncology, immunology, infectious disease, neurology, or biodistribution studies, the NEWTON series can accommodate them all.
All-in-one platform
Multi-modal capabilities
High sensitivity
Non-invasive imaging
Animal capacity up to 10 mice
Applications of the NEWTON Series
The NEWTON optical imaging platform supports a wide range of applications across preclinical research.
- Visualize both molecular activity and anatomical structures
- Enable longitudinal, non-invasive studies
- Support diverse applications from oncology to pharmacokinetics
Features and Benefits
Across all systems, the NEWTON platform is built on consistent, NIST-traceable calibrated optics and high-performance architecture.
- Bioluminescence imaging (BLI) for ultra-sensitive detection (multiplex imaging supports combined BLI + fluorescence workflow)
- Fluorescence imaging in VIS and NIR-I ranges (up to ~8 channels across 400–900 nm)
- 3D optical tomography for volumetric imaging
- SWIR (NIR-II) imaging for deep tissue visualization (extends up to 1700 nm with dedicated InGaAs SWIR detector)
Ultra-Sensitive Optical Performance
Engineered to detect even the lowest levels of signal.
- High-sensitivity, scientific-grade CCD cameras
- Deeply cooled detectors (down to -90°C) for ultra-low noise imaging
- Proprietary f/0.70 aperture lens for maximum light capture
- High-resolution imaging across all fields of view
Advanced Multispectral Imaging
Acquire multiple signals in sequence with precision.
- Multiple excitation and emission channels
- Narrow bandpass (VIS) or longpass (SWIR) filters for signal specificity
- Spectral unmixing for clear signal isolation
- Multi-reporter visualization in a single imaging session acquisition
Unlock Deeper Insights with SWIR Imaging
SWIR imaging expands the capabilities of optical imaging beyond conventional limits.
- Deeper tissue penetration compared to visible fluorescence
- Reduced autofluorescence for improved clarity
- Higher signal-to-noise ratio
- Real-time visualization of biological processes
*(SWIR available exclusively on FT-900)
Specifications
From acquisition and quantitative analysis to animal preparation and positioning, NEWTON integrates the tools needed to support consistent, reproducible imaging from setup through analysis.
• Maximum: 20 x 20 cm
• Minimum: 6 x 6 cm
• Up to 10-mouse capacity
• Heated mouse pad (+37°C)
• Individually controlled anesthesia manifolds
• Proprietary Optics: V.070
• Widest lens aperture on the market (f/0.7)
• 3D BLI Tomography
• License-free and user-friendly
• 3D BLI topography module
• Advanced software for absolute quantification
• Fully GLP and CFR21-compliant
• Data export in 16-bit .tiff or 8-bit .jpg formats
Specifications for the NEWTON FT-900
*Detailed specifications for all other models below.
Which Configuration is Best for Your Research
From compact systems to fully integrated SWIR imaging, the NEWTON optical imaging platform series is designed to evolve alongside your research.
- Start with a cost-effective entry system
- Scale to multi-animal and multimodal imaging
- Expand into advanced deep-tissue and functional imaging
NEWTON is not just a product; it is a platform built for long-term scientific discovery.
- X-RAY
- NIR I
- SWIR



Complete Newton Series & Specfications
Designed for a Smarter Imaging Workflow
| FEATURES | IR-500 | FT-900 | FT-500 | FT-100 | FT-30 | BIO FT-500 PLANT | BT-500 | BT-100 |
|---|---|---|---|---|---|---|---|---|
| IMAGING | ||||||||
| Modes | 2D Bioluminescence Imaging | |||||||
| 3D Bioluminescence Tomography | ||||||||
| 2D VIS/NIR Fluorescence imaging (400 to 900nm) | ||||||||
| Optional X-Ray | Optional X-Ray | |||||||
| 2D SWIR/NIR-II Fluorescence imaging (900 to 1700nm) | ||||||||
| OPTICS | ||||||||
| VIS Camera | DarQ-11 Scientific 16-Bit CCD Camera | |||||||
| Grade 0 / 400-900nm / 4.8 OD | ||||||||
| Cooling: -90°C Absolute | ||||||||
| Lens Aperture: f/0.70 | ||||||||
| Resolution: 2160 x 2160 (4.6 Megapixels) | ||||||||
| SWIR Camera | InGAas SWIR CCD Camera | |||||||
| 900-2000nm | ||||||||
| Cooling: -55°C Absolute | ||||||||
| Lens Aperture: f/0.70 | ||||||||
| Resolution: 640x512 (0,3 Megapixels) | ||||||||
| Species Capacity | 1-5 Mice (up to 10 with optional PAD) | 1-3 Mice | Whole-Plant Imaging | 1-5 Mice (up to 10 with optional PAD) | 1-3 Mice | |||
| Field of View | 6 x 6cm to 20 x 20cm | 12 x 12cm | 6 x 6cm to 20 x 20cm | 12 x 12cm | ||||
| DARKROOM | ||||||||
| Motorization | Motorized Camera (Z-Axis) | Fixed Camera | Motorized Camera (Z-Axis) | Fixed Camera | ||||
| Motorized Animal Stage (X/Y-Axis) | Fixed Animal Stage | Motorized Plant Stage (Z-Axis) | Motorized Animal Stage (X/Y-Axis) | Fixed Animal Stage | ||||
| Filter-Wheel | Motorized Filter-Wheel (11 Positions) | Motorized Filter-Wheel (15 Positions) | Motorized Filter-Wheel (11 Positions) | Motorized Filter-Wheel (10 Positions) | Motorized Filter-Wheel (11 Positions) | |||
| White-Light | Backlight LEDs for Brightfield Image | |||||||
| EXCITATION | ||||||||
| Fluorescence | 5 Fluorescent channels | 12 Excitation channels | 8 Excitation channels | Upgradeable to Fluorescence | ||||
| 680 / 740 / 780 / 880 / 980nm | 440 / 480 / 540 / 580 / 640 / 680 / 740 / 780 / 840 / 880 / 940 / 980nm | 440 / 480 / 540 / 580 / 640 / 680 / 740 / 780nm | 400 - 900nm | |||||
| On-demand Customization to 1000nm | ||||||||
| EMISSION | ||||||||
| Filters | 6 Narrow Band-pass filters | 14 Narrow Band-pass filters | 8 Narrow Band-pass filters | 4 Narrow Band-pass filters | ||||
| 1000 / 1100 / 1200 / 1300 / 1400 / 1500nm | 500 / 550 / 600 / 650 / 700 / 750 / 800 / 850 / 1000 / 1100 / 1200 / 1300 / 1400 / 1500nm | 500 / 550 / 600 / 650 / 700 / 750 / 800 / 850nm | 550 / 600 / 650 / 700nm | |||||
| HANDLING | ||||||||
| Heated Animal Stage (+37°C) | Tilting Plant Pot Holder | Heated Animal Stage (+37°C) | ||||||
| Animal Nose Cone Breathers (5 positions) | Animal Nose Cone Breathers (3 positions) | Flat Sample Tray | Animal Nose Cone Breathers (5 positions) | Animal Nose Cone Breathers (3 positions) | ||||
| 10 Position Mousepad Available | 30° Tilting Plant Holder | |||||||
| X-RAY MODULE | ||||||||
| Optional X-Ray | FT-500X | BT-500X | ||||||
| Energy range: 10-50 kVp | Energy range: 10-50 kVp | |||||||
| Current range: 0.1-1 mA | Current range: 0.1-1 mA | |||||||
| Pixel pitch: 84 µm | Pixel pitch: 84 µm | |||||||
*Information and specifications are subject to change without notice. Please contact us for the latest and most up to date information.
Supporting Consistent, Reproducible Imaging
Integrated acquisition and analysis tools, together with optimized animal handling, help standardize imaging conditions and support reliable quantitative results across studies.
Integrated Software & Quantitative Analysis
Optimized Animal Handling & Workflow
Optimized Animal Handling & Workflow
Built to support reliable and efficient in vivo imaging.
- Multi-animal imaging workflows
- Temperature-controlled animal platforms
- Integrated anesthesia compatibility
- Motorized positioning for consistent imaging
Animal Platform
All the animal pads of the NEWTON systems are designed for optimal physiological conditions and safety for small animals throughout your entire imaging workflow. You can choose from a wide selection of pads compatible with rodents (mice, rats, guinea pigs, small rabbits) but also with zebra fish, organs and tissue sections ex vivo and in vitro samples (e.g., microplates, etc.)
Temperature
≃37°C Pad temperature control (from 20 to 40°C)
Animal Capacity
3 to 10 mice at once (or 1 to 3 rats)
Warranty
2-year warranty
Pad Designs
6 different pad designs available
Related Research & Learning
Explore recent webinars, publications, and articles related to the NEWTON Series.
Publication Highlight: Long-Term Optical Imaging Reveals Bone Marrow Clearance and Extramedullary Escape in BCMA CAR-NK Therapy
Publication Highlight: The role of phosphodiesterase 5 inhibitors in attenuating obesity-induced metabolic disorders
The Newton 7.0 Optical Imaging System: Championing the 3Rs to Drive the Future of New Approach Methodologies
Article: The miR6445-NAC029 module regulates drought tolerance by regulating the expression of glutathione S-transferase U23 and reactive oxygen species scavenging in Populus The miR6445-NAC029 module regulates drought tolerance by regulating the expression of glutathione S-transferase U23 and reactive oxygen species scavenging in Populus
Immunological Tolerance to Luciferase and Fluorescent Proteins using Tol Mice Enables Development of Improved Tumor Models for Investigating Immunity and Metastasis