Optical Imaging
NEWTON 7.0 Series
Optical Imaging (BLI and FLI in VIS, NIR-I & SWIR)
Advanced bioluminescence, visible fluorescence, NIR-I, and SWIR imaging for preclinical research
Quick Resources
Access key Iconeus resources and technical documents
Brochure
Product overview and key capabilities.
References
Publications and supporting research.
NEWTON 7.0 System Overview
The NEWTON 7.0 series offers advanced bioluminescence, fluorescence multispectral imaging, and optional X-Ray capabilities for a wide range of applications.
Built on a shared technological foundation, NEWTON 7.0 systems deliver consistent performance, scalable configurations, and reliable quantitative results for diverse in vivo, ex vivo, and in vitro applications. Designed for longitudinal preclinical research, the NEWTON 7.0 systems deliver non-ionizing and non-invasive visualization of biological processes in the visible, near infrared and short-wave infrared spectra (VIS / NIR / SWIR). Whether your focus is oncology, immunology, infectious disease, neurology, or biodistribution studies, the NEWTON 7.0 series can accommodate them all.
All-in-one platform
Multi-modal capabilities
High sensitivity
Non-invasive imaging
Animal capacity up to 10 mice
Applications of the NEWTON 7.0 Series
The NEWTON optical imaging platform supports a wide range of applications across preclinical research.
- Visualize both molecular activity and anatomical structures
- Enable longitudinal, non-invasive studies
- Support diverse applications from oncology to pharmacokinetics
Features and Benefits
Across all systems, the NEWTON platform is built on consistent, NIST-traceable calibrated optics and high-performance architecture.
- Bioluminescence imaging (BLI) for ultra-sensitive detection (multiplex imaging supports combined BLI + fluorescence workflow)
- Fluorescence imaging in VIS and NIR-I ranges (up to ~8 channels across 400–900 nm)
- 3D optical tomography for volumetric imaging
- SWIR imaging for deep tissue visualization (extends up to 1700 nm with dedicated InGaAs SWIR detector)
Ultra-Sensitive Optical Performance
Engineered to detect even the lowest levels of signal.
• High-sensitivity, scientific-grade CCD cameras
• Deeply cooled detectors (down to -90°C) for ultra-low noise imaging
• Proprietary f/0.70 aperture lens for maximum light capture
• High-resolution imaging across all fields of view
Advanced Multispectral Imaging
Acquire multiple signals in sequence with precision.
• Multiple excitation and emission channels
• Narrow bandpass (VIS) or longpass (SWIR) filters for signal specificity
• Spectral unmixing for clear signal isolation
• Multi-reporter visualization in a single imaging session acquisition
Unlock Deeper Insights with SWIR Imaging
SWIR imaging expands the capabilities of optical imaging beyond conventional limits.
Key Advantages
• Deeper tissue penetration compared to visible fluorescence
• Reduced autofluorescence for improved clarity
• Higher signal-to-noise ratio
• Real-time visualization of biological processes
*(SWIR available exclusively on FT-900)
System Specifications
Specifications for the NEWTON FT-900. Please see the specifications for the other models below.
• Maximum: 20 x 20 cm
• Minimum: 6 x 6 cm
• Up to 10-mouse capacity
• Heated mouse pad (+37°C)
• Individually controlled anesthesia manifolds
• Proprietary Optics: V.070
• Widest lens aperture on the market (f/0.7)
• 3D BLI Tomography
• License-free and user-friendly
• 3D BLI topography module
• Advanced software for absolute quantification
• Fully GLP and CFR21-compliant
• Data export in 16-bit .tiff or 8-bit .jpg formats
How to Choose Between the Systems
With a clear upgrade path, from compact systems to fully integrated SWIR imaging, the NEWTON 7.0 optical imaging platform is designed to evolve alongside your research.
• Start with a cost-effective entry system
• Scale to multi-animal and multimodal imaging
• Expand into advanced deep-tissue and functional imaging
NEWTON 7.0 is not just a product; it is a platform built for long-term scientific discovery.
- X-RAY
- NIR I
- SWIR
Compare Newton Models
Shared specifications span the models they apply to, so repeated content appears only once. Model-specific differences remain in separate cells for faster comparison.
| FEATURES | IR-500 | FT-900 | FT-500 | FT-100 | FT-30 | BIO FT-500 PLANT | BT-500 | BT-100 |
|---|---|---|---|---|---|---|---|---|
| IMAGING | ||||||||
| Modes | 2D Bioluminescence Imaging | |||||||
| 3D Bioluminescence Tomography | ||||||||
| 2D VIS/NIR Fluorescence imaging (400 to 900nm) | ||||||||
| Optional X-Ray | Optional X-Ray | |||||||
| 2D SWIR/NIR-2 Fluorescence imaging (900 to 1700nm) | ||||||||
| OPTICS | ||||||||
| VIS Camera | DarQ-11 Scientific 16-Bit CCD Camera | |||||||
| Grade 0 / 400-900nm / 4.8 OD | ||||||||
| Cooling: -90°C Absolute | ||||||||
| Lens Aperture: f/0.70 | ||||||||
| Resolution: 2160x2160 (4.6 Megapixels) | ||||||||
| SWIR Camera | InGAas SWIR CCD Camera | |||||||
| 900-2000nm | ||||||||
| Cooling: -55°C Absolute | ||||||||
| Lens Aperture: f/0.70 | ||||||||
| Resolution: 640x512 (0,3 Megapixels) | ||||||||
| Species Capacity | 1-5 Mice (up to 10 with optional PAD) | 1-3 Mice | Whole-Plant Imaging | 1-5 Mice (up to 10 with optional PAD) | 1-3 Mice | |||
| Field of View | 6 x 6cm to 20 x 20cm | 12 x 12cm | 6 x 6cm to 20 x 20cm | 12 x 12cm | ||||
| DARKROOM | ||||||||
| Motorization | Motorized Camera (Z-Axis) | Fixed Camera | Motorized Camera (Z-Axis) | Fixed Camera | ||||
| Motorized Animal Stage (X/Y-Axis) | Fixed Animal Stage | Motorized Plant Stage (Z-Axis) | Motorized Animal Stage (X/Y-Axis) | Fixed Animal Stage | ||||
| Filter-Wheel | Motorized Filter-Wheel (11 Positions) | Motorized Filter-Wheel (15 Positions) | Motorized Filter-Wheel (11 Positions) | Motorized Filter-Wheel (10 Positions) | Motorized Filter-Wheel (11 Positions) | |||
| White-Light | Backlight LEDs for Brightfield Image | |||||||
| EXCITATION | ||||||||
| Fluorescence | 5 Fluorescent channels | 12 Excitation channels | 8 Excitation channels | Upgradeable to Fluorescence | ||||
| 680 / 740 / 780 / 880 / 980nm | 440 / 480 / 540 / 580 / 640 / 680 / 740 / 780 / 840 / 880 / 940 / 980nm | 440 / 480 / 540 / 580 / 640 / 680 / 740 / 780nm | 400 - 900nm | |||||
| On-demand Customization to 1000nm | ||||||||
| EMISSION | ||||||||
| Filters | 6 Narrow Band-pass filters | 14 Narrow Band-pass filters | 8 Narrow Band-pass filters | 4 Narrow Band-pass filters | ||||
| 1000 / 1100 / 1200 / 1300 / 1400 / 1500nm | 500 / 550 / 600 / 650 / 700 / 750 / 800 / 850 / 1000 / 1100 / 1200 / 1300 / 1400 / 1500nm | 500 / 550 / 600 / 650 / 700 / 750 / 800 / 850nm | 550 / 600 / 650 / 700nm | |||||
| HANDLING | ||||||||
| Heated Animal Stage (+37°C) | Tilting Plant Pot Holder | Heated Animal Stage (+37°C) | ||||||
| Animal Nose Cone Breathers (5 positions) | Animal Nose Cone Breathers (3 positions) | Flat Sample Tray | Animal Nose Cone Breathers (5 positions) | Animal Nose Cone Breathers (3 positions) | ||||
| 10 Position Mousepad Available | 30° Tilting Plant Holder | |||||||
| X-RAY MODULE | ||||||||
| Optional X-Ray | FT-500X | BT-500X | ||||||
| Energy range: 10-50 kVp | Energy range: 10-50 kVp | |||||||
| Current range: 0.1-1 mA | Current range: 0.1-1 mA | |||||||
| Pixel pitch: 84 µm | Pixel pitch: 84 µm | |||||||
* Information and specifications are subject to change without notice. Please contact us if you have any questions.
Components
Expand your research capabilities with Integrated software and optimized animal handling.
Integrated Software & Quantitative Analysis
Optimized Animal Handling & Workflow
Optimized Animal Handling & Workflow
Built to support reliable and efficient in vivo imaging.
• Multi-animal imaging workflows
• Temperature-controlled animal platforms
• Integrated anesthesia compatibility
• Motorized positioning for consistent imaging
Animal Platform
All the animal pads of our NEWTON 7.0 systems are designed to guarantee optimal physiological conditions and safety for small animals throughout your entire imaging workflow. You can choose from a wide selection of pads compatible with rodents (mice, rats, guinea pigs, small rabbits) but also with zebra fish, organs and tissue sections ex vivo and in vitro samples (e.g., microplates, etc.)
Temperature
≃37°C Pad temperature control (from 20 to 40°C)
Animal Capacity
3 to 10 mice at once (or 1 to 3 rats)
Warranty
2-year warranty
Pad Designs
6 different pad designs available
Related Research & Learning
Explore recent webinars, publications, and articles related to the Rodent Surgical Monitor.
(April 9th, 2026) Webinar: Driving NAMs-Aligned Preclinical Research with the Newton 7.0 Optical Imaging Systems
Publication Highlight: T Cell-specific Non-viral DNA Delivery & In Vivo CAR-T Generation Using Targeted Lipid Nanoparticles